On-line contextual Help

/

Abutment 

GEO5

Geotechnical software

« Back to Help

Analysis of walls (support structures)

Load reduction (DA1, DA2, DA3):

All design approaches consider partial factors reducing load. These are used to multiply all forces entering the analysis. For actual verification of individual modes of failure the program determines, whether the force or pressure acts favorably or unfavorably. Depending on that these actions are then multiplied by the corresponding partial factor. Information regarding the applied partial factors is stored in the analysis protocol.

Analysis protocolAnalysis protocol

The frame analysis allows for defining "Secondary variable actions" – corresponding partial factors are then multipied by combination coefficients of load.

Reduction of material (DA1, DA3):

Soil parameters are automatically reduced by corresponding partial factors.

Reduction of resistance (DA2):

Corresponding magnitudes of resistant forces, moments and bearing capacities are reduced.

When performing the analysis according the Design approach 1, all verifications are carried out twice for both combinations of load. For a given limit state the highest stressed design is displayed on the desktop.




Language: english