GEO5 Software

Online Help

Tree
Settings
Program:
Language:

SPT

The “SPT” frame is used to enter and manage standard penetration tests (SPT) that are used directly in the analyses of the current task.

Tests can be added using the “Add SPT” button or imported from the common “Field Tests” frame using the “Adopt from Field Tests” button. Only SPT tests can be imported.

The individual tests are listed in a table and can then be edited or removed. In the “Visualized field test” column, you select the test whose results are shown in the graphical part.

When adding or editing a test, you enter its name, the offset of the origin, the measured values at individual depths, and, if applicable, other parameters (test equipment data, fines content, etc.).

The tests in this frame contain all data that can be used in the analyses and methods available for the current task. Whether the data are required depends on the currently selected analysis and method. Required data are shown in regular font, optional data in italics. Changing the analysis or method may therefore change which test data must be entered.

Note: This frame already shows the final number of blows used in the analysis (n). The individual blow counts from which this number can be calculated can be entered in the “Field Tests” frame above.

Frame “SPT”

When the “Show average values” option is checked, the graphical part shows the averaged values that are used in the analysis when multiple SPT tests are used.

Standard penetration test (SPT) results can be imported in various formats (e.g., *.TXT, *.CSV, *.XLSX, *.ODS) directly when adding or editing a test using the button.

SPT tests can be transferred within GEO5 programs using "FineClipboard".

Try GEO5 software for free.